7.3.6

Replacing the redundant power supply module

If a fault or an error has been reported for the redundant power supply, the LED of the
defective module lights up, see section "Power indicators, redundant power supply
(Page 17)". The device also works with the second, non-defective module.
Note
However, to ensure the availability of your system through the redundant power supply,
replace the defective power supply module with a functioning new module as soon as
possible.
• You can continue to operate the device until you can shut it down properly.
• The replacement of one of the two modules of the redundant power supply can be
performed, however, without shutting down the device.
Requirement
● The power supply lines are connected, see section "Connecting a redundant power
supply (Page 35)"
Procedure
Removal
1. Use the LEDs to determine which
2. Alternatively, shut down the device.
3. Acknowledge the warning signal on the
4. Tilt the handle
5. Unlock the power supply module at the
6. Slide the new power supply module
7. Reconnect the power plug
Both LEDs
SIMATIC IPC1047
Operating Instructions, 07/2019, A5E45118479-AB
module is defective, e.g. the LED
lights red.
The LED
can also flash red be-
cause there is a warning, e.g. over-
load.
Disconnect the power plug
power supply module to be replaced.
LED
.
forward.
pin
and pull the module
forward out of the frame by the handle
.
into the frame all the way to the rear
until it clicks into place.
Alternatively, restart the device.
and
light in green again.
from the
straight
.
Device maintenance and repair
7.3 Removing and installing hardware
89