5.3.1.6

Integrating a new hard disk drive in the RAID system

The RAID system is configured in the delivery state so that a new hard disk must be
integrated manually in case of an error. To integrate the hard disk automatically, activate
"Automatic rebuild" in the "Preferences" menu of the RAID software.
Automatic integration of a hard disk
NOTICE
Data loss
The hard disk to be integrated is not checked for partition information or existing data
during automatic integration.
All partitions and data on the hard disk are deleted without warning. Insert only a brand-new
hard disk.
Requirement:
● "Automatic rebuild" is selected in the "Preferences" menu of the RAID software.
● The hard disk to be integrated is brand new or is set up as a spare drive. Notes on
creating spare drives are available in the controller documentation.
Sequence
The following figure is an example for the automatic rebuilding process.
A defective hard disk is still displayed during the rebuilding process. This display disappears
when the rebuilding process is completed.
SIMATIC IPC1047
Operating Instructions, 07/2019, A5E45118479-AB
Operating the device
5.3 Operating RAID systems
49