Section 7: Troubleshooting the Commander Device
7.7
FITTINGS
ISSUE
I'm trying to scan a Turbo Electronic Flush Valve, but
nothing happens.
My Commander Unit is working, but I cannot scan the
fitting.
When I scan, and fitting is in CLEAN MODE or PIPE CLEAN
MODE, I do not see the mode register as the current
setting.
When I try to set both upper and lower beams to "OFF",
the upper beam always stays "ON".
When I scan, the Status ERROR does not match the
visual cues. Example: continual blinking light from module,
ERROR = "LOW BATTERY"
Chicago Faucets
Commander
Handheld Programming Unit User Guide
®
REASON
Turbo is not supported by Commander Handheld.
Fitting power is too low (< 3.2V).
Fitting is set to an unusual running mode.
Fitting module is defective.
Fitting sensing is malfunctioning or environment is affecting
sensing.
These modes are not recorded in scan records.
Not possible to have upper and lower beams off at the same
time.
Fitting module is defective.
SOLUTION
Turbo is only compatible with the previous PALM version of
the software.
Set power to proper level ASAP.
Wait 2 minutes and try again. If still not working, Perform
FAC or CUR RESET.
Replace module.
Remove and reinstall shut-off screw, allow for calibration.
These modes are temporary and so no record is made.
Only the current mode settings will show, i.e. what the
fitting will return to at the end of the execution of the
CLEAN command.
Allowed configurations are:
• upper/lower ON/OFF
• upper/lower and OFF/ON
Replace module.
Page 43