Overview

Chicago Faucets deck mounted faucets feature cast brass bodies and precision cartridges for years of reliable
operation. Metering models with adjustable cycle time offer true water savings.

Notice to the Installer

• Make sure there is enough space and lighting available during installation and service
• Do not modify or convert this Chicago Faucets product yourself. All warranties will be voided.
Pressurized plumbing fixtures shall be installed in accordance with manufacturer's recommendations. The supply piping
to these devices shall be securely anchored to the building structure to prevent installed device from unnecessary
movement when operated by the user. Care shall be exercised when installing the device to prevent marring the
exposed surface.
NOTE: The information in this manual is subject to change without notice.
Please leave this manual with the facility manager after completing the faucet installation. This document contains
information necessary for routine maintenance and servicing.
NOTE: Before installation, turn off water supplies to existing faucet and remove faucet if replacing. Clean faucet basin
and clear away debris. Flush all supply lines before connecting to faucet. Failure to do so can result in debris clogging
the inlets and/or cartridges.
NOTE: Before installing a new ceramic cartridge flush lines completely.

Safety Information

Read this entire user guide to ensure proper installation. Compliance and conformity to local codes and ordinances is
the responsibility of the installer.
The following safety notes must always be complied with during handling of this product:
• FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate this equipment.
• Make sure there is enough space and lighting available during installation and service.
• Do not modify or convert this Chicago Faucets product yourself. All warranties will be voided.
Internal Antenna Specifications
• Peak Gain of the antenna: -5.47 dBi
• Frequency range: 2400-2500 MHz
• FCC ID: 2APTX-CFC01
Important
• Installation may be performed at different times of construction by different individuals. For this reason, these
instructions should be left on-site with the facility or maintenance manager.
• Pressurized plumbing fixtures shall be installed in accordance with manufacturer's recommendations. The supply
piping to these devices shall be securely anchored to the building structure to prevent installed device from
unnecessary movement when operated by the user. Care shall be exercised when installing the device to prevent
marring the exposed significant surface.
• Do not use pipe dope.
• Flush all the water supply lines before making connections.
This faucet comes with all the components needed for installation, however, some tools and supplies are not included.
• Basin Wrench
• Adjustable Wrench
• Adjustable Locking Pliers
NOTE: Do not use pipe dope on faucet and supply connections.
Possible solenoid contamination could occur and will void any warranty.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
For additional technical assistance, call 800/TEC-TRUE (800-832-8783) or visit our website at chicagofaucets.com.
1
• Plumber's Putty
• Hex Key (supplied)
• Aerator Key (supplied)
Traditional
Lavatory
Contemporary
Lavatory
Edge
Curve
Gooseneck
Wall Mount

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHICAGO FAUCETS HyTronic Traditional Lavatory and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Geberit CHICAGO FAUCETS HyTronic Traditional Lavatory

  • Page 1 HyTronic User Guide Installation Instructions ® For single supply and dual supply HyTronic faucets Overview Chicago Faucets deck mounted faucets feature cast brass bodies and precision cartridges for years of reliable operation. Metering models with adjustable cycle time offer true water savings. Notice to the Installer •...
  • Page 2 HyTronic User Guide Installation Instructions ® (continued) Mounting of Lavatory and Gooseneck Faucet Important Prerequisites • It is not necessary to unscrew the connection between braided hose and housing • Supply valve is installed to install the product. • Water supply lines are flushed properly •...
  • Page 3 HyTronic User Guide Installation Instructions ® (continued) Mounting of Long Term Power System (LTPS) Pack (LTPS Models Only) The LTPS Power Pack comes with mounting hardware (screws and anchors). You will need a drill and Phillips screwdriver to complete the installation.
  • Page 4 HyTronic User Guide Installation Instructions ® (continued) Mounting of SSPS Generator The SSPS Generator comes with all the components needed for Includes IMPORTANT: Do not use pipe installation, however, some tools and supplies are not included. • SSPS Generator Unit dope on faucet and supply •...
  • Page 5 HyTronic User Guide Installation Instructions ® (continued) Start-up Operation A traditional lavatory faucet is shown as an example. The start-up operation applies to all models. Prerequisites • Faucet is mounted • Water supply is on • Water supply lines are flushed properly •...
  • Page 6 • Water supply valve is open Remove shut-off screw • Battery is full (LED does not blink) for DC faucets Remove housing vertically • AC power is on for AC faucets HyTronic User Guide Installation Instructions ® Remove shut-off screw Adjusting Water Temperature (Internal Mixer) Remove mixer handle (only for faucets with (continued)
  • Page 7 Mount mixer handle Result Cleaning or Replacing Outlet The temperature is now adjusted. is now replaced. Remove shut-off screw Carefully test the new temperature. If necessary, adjust again HyTronic User Guide Installation Instructions ® Adjust internal mixer with screwdriver Connect braided hoses with filter to supply valves and Clockwise >...
  • Page 8 TROUBLESHOOTING No Water Flow Water Runs Continuously Cause Solution Cause Solution Supply valves are closed Open supply valves. Interfering object is in Remove object from monitoring area. Remove and monitoring range re-install shut-off screw. Do not disturb scanning Aerator is blocked or dirty Clean or replace outlet.