Table 18. Sensor information, event description, and service action for the 8001-12C and 8005-12N (continued)
Sensor name (Sensor ID)
v Freq Limit OT 1 (0xA8)
v Mem Thrttl OT 1 (0xAA)
v Freq Limit OT 2 (0xAC)
v Mem Thrttl OT 2 (0xAE)
v Freq Limit Pwr 1 (0xA9)
v Freq Limit Pwr 2 (0xAD)
38
Problem analysis, system parts, and locations for the 8001-12C, 8001-22C, 8005-12N, and 8005-22N
Event description
Performance Met
Performance Lags
Performance Met
Performance Lags
Service action
If Asserted is in the event
description, no service action is
required.
If Deasserted is in the event
description, ensure that the ambient
temperature is within operating
specifications. Ensure that there are
no blockages to the air inlet and
outlets. If blockages are found,
remove them. Ensure that all of the
fans are working properly by looking
for serviceable events related to fans
and resolving them.
If Deasserted is in the event
description, no service action is
required.
If Asserted is in the event
description, ensure that the ambient
temperature is within operating
specifications. Ensure that there are
no blockages to the air inlet and
outlets. If blockages are found,
remove them. Ensure that all of the
fans are working properly by looking
for serviceable events related to fans
and resolving them.
If Asserted is in the event
description, no service action is
required.
If Deasserted is in the event
description, ensure that both power
supplies are working properly. Search
for serviceable events related to
system power and voltage and
resolve them. Ensure all fans are
working properly by looking for
serviceable events related to fans and
resolving them.
If Deasserted is in the event
description, no service action is
required.
If Asserted is in the event
description, ensure that both power
supplies are working properly. Search
for serviceable events related to
system power and voltage and
resolve them. Ensure all fans are
working properly by looking for
serviceable events related to fans and
resolving them.