IBM Power Systems 8001-12C Manual page 48

Problem analysis, system parts, and locations
Hide thumbs Also See for Power Systems 8001-12C:
Table of Contents

Advertisement

Table 18. Sensor information, event description, and service action for the 8001-12C and 8005-12N (continued)
Sensor name (Sensor ID)
v P1M1-DIMMA Func (0x10)
v P1M1-DIMMB Func (0x11)
v P1M1-DIMMC Func (0x12)
v P1M1-DIMMD Func (0x13)
v P1M2-DIMMA Func (0x14)
v P1M2-DIMMB Func (0x15)
v P1M2-DIMMC Func (0x16)
v P1M2-DIMMD Func (0x17)
v P2M1-DIMMA Func (0x18)
v P2M1-DIMMB Func (0x19)
v P2M1-DIMMC Func (0x1A)
v P2M1-DIMMD Func (0x1B)
v P2M2-DIMMA Func (0x1C)
v P2M2-DIMMB Func (0x1D)
v P2M2-DIMMC Func (0x1E)
v P2M2-DIMMD Func (0x1F)
VBAT (0x33)
Backplane Fault (0x34)
32
Problem analysis, system parts, and locations for the 8001-12C, 8001-22C, 8005-12N, and 8005-22N
Event description
Configuration Error
v Transition to Non-recoverable
v Lower Non-recoverable – going
low
v Lower Non-critical – going low
v Lower Non-critical – going high
v Lower Critical – going low
v Lower Critical – going high
v Lower Non-recoverable – going
high
v Upper Non-critical – going low
v Upper Non-critical – going high
v Upper Critical - going low
v Upper Critical - going high
v Upper Non-recoverable – going
low
v Upper Non-recoverable – going
high
State Deasserted
State Asserted
Service action
Complete the following steps:
1. If the sensor name is
P1M1-DIMMA Func, ensure that
P1M1-DIMMA is seated properly.
If the sensor name is
P1M1-DIMMB Func, ensure that
P1M1-DIMMB is seated properly.
And so on.
2. If you recently installed or
replaced memory DIMMs, ensure
that the DIMMs are plugged in
the correct memory slots.
3. If the sensor name is
P1M1-DIMMA Func, replace
P1M1-DIMMA. If the sensor
name is P1M1-DIMMB Func,
replace P1M1-DIMMB. And so on.
Go to "8001-12C or 8005-12N
locations" on page 73 to identify
the physical location and removal
and replacement procedure.
Replace the time-of-day battery. Go
to "8001-12C or 8005-12N locations"
on page 73 to identify the physical
location and removal and
replacement procedure.
No service action is required.
No service action is required.
Replace the system backplane. Go to
"8001-12C or 8005-12N locations" on
page 73 to identify the physical
location and removal and
replacement procedure.