Table 16. OEM record de specific log information and service action
OEM record de specific log information
00xxxxxxxxxx
01xxxxxxxxxx
04xxxxxxxxxx
05xxxxxxxxxx
08xxxxxxxxxx
09xxxxxxxxxx
0Axxxxxxxxxx
10xxxxxxxxxx
16xxxxxxxxxx
1Cxxxxxxxxxx
22xxxxxxxxxx
2Dxxxxxxxxxx
30xxxxxxxxxx
31xxxxxxxxxx
34xxxxxxxxxx
37xxxxxxxxxx
3Fxxxxxxxxxx
22
Problem analysis, system parts, and locations for the 8001-12C, 8001-22C, 8005-12N, and 8005-22N
Service action
Go to Getting fixes and update the system firmware to
the most recent level of firmware that is available. If this
SEL event continues to be logged, go to "Collecting
diagnostic data" on page 71. Then, go to "Contacting
IBM service and support" on page 71.
Go to the "EPUB_PRC_FIND_DECONFIGURE_PART
isolation procedure" on page 61.
Go to the "EPUB_PRC_SP_CODE isolation procedure"
on page 61.
Go to the "EPUB_PRC_PHYP_CODE isolation
procedure" on page 61.
Go to the "EPUB_PRC_ALL_PROCS isolation procedure"
on page 62.
Go to the "EPUB_PRC_ALL_MEMCRDS isolation
procedure" on page 62.
Go to Getting fixes and update the system firmware to
the most recent level of firmware that is available. If this
SEL event continues to be logged, go to "Collecting
diagnostic data" on page 71. Then, go to "Contacting
IBM service and support" on page 71.
Go to the "EPUB_PRC_LVL_SUPPORT isolation
procedure" on page 63.
Go to Getting fixes and update the system firmware to
the most recent level of firmware that is available. If this
SEL event continues to be logged, go to "Collecting
diagnostic data" on page 71. Then, go to "Contacting
IBM service and support" on page 71.
Go to Getting fixes and update the system firmware to
the most recent level of firmware that is available. If this
SEL event continues to be logged, go to "Collecting
diagnostic data" on page 71. Then, go to "Contacting
IBM service and support" on page 71.
Go to the "EPUB_PRC_MEMORY_PLUGGING_ERROR
isolation procedure" on page 63.
Go to the "EPUB_PRC_FSI_PATH isolation procedure"
on page 63.
Go to the "EPUB_PRC_PROC_AB_BUS isolation
procedure" on page 64.
Go to the "EPUB_PRC_PROC_XYZ_BUS isolation
procedure" on page 64.
Go to Getting fixes and update the system firmware to
the most recent level of firmware that is available. If this
SEL event continues to be logged, go to "Collecting
diagnostic data" on page 71. Then, go to "Contacting
IBM service and support" on page 71.
Go to the "EPUB_PRC_EIBUS_ERROR isolation
procedure" on page 65.
Go to the "EPUB_PRC_POWER_ERROR isolation
procedure" on page 66.
Need help?
Do you have a question about the Power Systems 8001-12C and is the answer not in the manual?
Questions and answers