IBM Power Systems 8001-12C Manual page 47

Problem analysis, system parts, and locations
Hide thumbs Also See for Power Systems 8001-12C:
Table of Contents

Advertisement

Table 18. Sensor information, event description, and service action for the 8001-12C and 8005-12N (continued)
Sensor name (Sensor ID)
v P1M1-DIMMA Func (0x10)
v P1M1-DIMMB Func (0x11)
v P1M1-DIMMC Func (0x12)
v P1M1-DIMMD Func (0x13)
v P1M2-DIMMA Func (0x14)
v P1M2-DIMMB Func (0x15)
v P1M2-DIMMC Func (0x16)
v P1M2-DIMMD Func (0x17)
v P2M1-DIMMA Func (0x18)
v P2M1-DIMMB Func (0x19)
v P2M1-DIMMC Func (0x1A)
v P2M1-DIMMD Func (0x1B)
v P2M2-DIMMA Func (0x1C)
v P2M2-DIMMB Func (0x1D)
v P2M2-DIMMC Func (0x1E)
v P2M2-DIMMD Func (0x1F)
Event description
v Memory Device Disabled
v Uncorrectable Memory Error
v Memory Scrub Failed
v State Deasserted
v Device Disabled
v Transition to Critical from Less
Severe
v Transition to Non-recoverable from
Less Severe
v Transition to Critical from
Non-recoverable
v Correctable Memory Error
v Parity
v Correctable Memory Error Logging
Limit Reached
v Memory Automatically Throttled
v Critical Over temperature
v Presence Detected
v Spare
v State Asserted
v Device Enabled
v Transition to OK
v Transition to Non-Critical from OK
v Transition to Non-Critical from
More Severe
v Monitor
v Informational
v Transition to Non-recoverable
v Predictive Failure
Service action
No service action is required.
If the sensor name is P1M1-DIMMA
Func, replace P1M1-DIMMA. If the
sensor name is P1M1-DIMMB Func,
replace P1M1-DIMMB. And so on.
Go to "8001-12C or 8005-12N
locations" on page 73 to identify the
physical location and removal and
replacement procedure.