Resolving A Raid Adapter Problem - IBM Power Systems 8001-12C Manual

Problem analysis, system parts, and locations
Hide thumbs Also See for Power Systems 8001-12C:
Table of Contents

Advertisement

Table 3. Resource names, examples, and service procedures for different types of operating system
logs. (continued)
Resource name
nvme
ata1, ata2
sda, sdb, sdc
3. Are all of the adapters in the system missing or failed?
If
Then
Yes:
Perform the following actions, one at a time until the problem is resolved:
1. Ensure that the PCIe risers are fully seated in the system.
2. Replace system processor CPU 1.
3. Replace the system backplane.
Note:
v If your system is an 8001-12C or 8005-12N, go to "8001-12C or 8005-12N locations" on
v If your system is an 8001-22C or 8005-22N, go to "8001-22C or 8005-22N locations" on
No:
Go to "Collecting diagnostic data" on page 71. Then, go to "Contacting IBM service and
support" on page 71.

Resolving a RAID adapter problem

Learn about the possible problems and service actions that you can perform to resolve a RAID adapter
problem.
Note: To determine the location of the PCIe adapter, see "Identifying the location of the PCIe adapter by
using the slot number" on page 18.
Table 4. RAID adapter problems and service actions.
Problem
System unable to find adapter
12
Problem analysis, system parts, and locations for the 8001-12C, 8001-22C, 8005-12N, and 8005-22N
Example of a log requiring
a service action
Failed status: ffffffff,
reset controller
SError: { RecovComm
PHYRdyChg 10B8B Dispar }
FAILED Result
page 73 to identify the physical location and the removal and replacement procedure.
page 87 to identify the physical location and the removal and replacement procedure.
Type of problem
NVMe Flash adapter
Marvell storage adapter
Storage
Service action
1. Verify that the adapter is properly seated in a
compatible slot.
2. Install the adapter in a different compatible slot.
3. Verify that the drivers for the adapter are installed.
4. Verify that the most recent firmware is installed on
the system, or install the most recent firmware if it is
not already installed.
5. Restart the system.
6. Replace the adapter.
7. Replace the system backplane.
8. Replace the central processing unit (CPU).
Service procedure
Go to "Resolving an NVMe
Flash adapter problem" on
page 15.
Go to "Resolving a storage
device problem" on page
16.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Power Systems 8001-12C and is the answer not in the manual?

Questions and answers