INSTALLATION, OPERATION MANUAL, MODEL ETP-10E

7.0 TROUBLESHOOTING

WATER FLOWS INTO COOKING COMPARTMENT:
1. Probes not sensing water, thereby not operating fill solenoid.
2. Scale build-up on operating probe inside generator.
3. Water fill solenoid valve is not closed. Check for scale or foreign particles lodged in
diaphragm or core tube of valve.
These problems are an indication of severe harmful water conditions which should be corrected
immediately to avoid damage to the components and performance of the steamer.
DOOR LEAKS:
1. Check for damage to door gasket.
2. Clogged compartment drain or plumbing.
WATER ACCUMULATES IN THE COMPARTMENT:
1. Compartment drain clogged.
WATER FLOWS INTO DRAIN DURING SHUTDOWN:
When steamer is shut down and cold water is running continuously into the open drain,
solenoid valve(s) did not close when steamer was turned off.
1. Disassemble solenoid valve(s) and examine for scale or foreign particles lodged in
diaphragm or core tube.
2. Clean valve(s) thoroughly and reassemble, or replace valve(s).
WATER NOT BEING SUPPLIED TO GENERATOR:
1. Water supply is "OFF".
2. Supply water pressure too low.
Part No. 10309R0