6.0 PREVENTIVE MAINTENANCE (Continued)
Use of cleaning agents that contain chloride, acids or salts which are corrosive may cause
pitting and corrosion when used over a period of time; this will reduce the life of the appliance.
Should pitting or corrosion occur, this is not covered by warranty.
Follow the recommended cleaning instructions. Use a mild detergent, warm water and rinse
thoroughly.
NEVER SPRAY WATER INTO ELECTRIC CONTROLS OR LOUVERS.
REMOVAL OF SCALE DEPOSITS
It is recommended that your steamer be delimed once a month, or more often if necessary.
Should your steamer develop a heavy build-up of lime scale deposits, use the TOTAL
CONCEPT TREATMENT KIT available from your authorized service agent.
Before beginning deliming procedures, ensure that water is not overflowing into the cooking
compartment.
DELIMING PROCEDURE
Both generators must be delimed individually.
WARNING: Read and follow instructions on the TOTAL CONCEPT
bottle. Use plastic or rubber gloves to avoid skin contact. If TOTAL
CONCEPT comes in contact with skin, rinse with clean water.
CAUTION: Do not open deliming caps when unit is in operation. Do
not open or close compartment doors when deliming caps are not in
place.
Part No. 10309R0