6.0 PREVENTIVE MAINTENANCE (Continued)
CAUTION: Do not open or close compartment doors or operate unit
when deliming caps are not in place.
1. Turn the power switch "OFF" for three minutes, allowing the generators to completely
empty.
2. Turn the power switch to the "DELIME" position.
3. Remove caps located on top right of steamer (left cap for top generator, right cap for bottom
generator.) Using a funnel and pouring slowly to avoid spilling, pour one quart (0.95 liters)
of Market Forge's Total Concept deliming solution into each generator.
4. Replace the deliming caps and tighten. Turn power switch to "ON" for five minutes allowing
the generator to completely fill.
5. Turn the power switch to the "DELIME" position. Unscrew the deliming caps and add one
quart (0.05 liters) of clean water for gas units, ½ quart (0.48 liters) for electric units.
6. Replace the deliming caps and tighten. Turn the power switch "ON" for 30 minutes. (Timer
in OFF position.)
7. Flush the generators three times. Turn power switch to "OFF" for three minutes and the
"ON" for five minutes.
WARNING: When this appliance is installed with casters and is
connected to the supply piping by means of a connector for
moveable appliances, a restraint to prevent damage to the
connector or quick disconnect device should have been installed. If
disconnection of the restraint is necessary, reconnect this restraint
after the appliance has been returned to its originally installed
position.