Image 7-12
4. Level out the ILite rental foot now in the transverse direction. Use the same adjustment possibilities as described in step 3.
Caution:
Do not place the spirit level upon the smaller foot profiles of the ILite rental foot but upon the main profile as illustrated.
5
Image 7-13
5. Align the top of the positioning pins of the neighboring ILite rental foot with the top of the positioning pins of the previous leveled
ILite rental foot. Use a spirit level (or ruler) of at least 100 cm and ensure that the spirit level captures at least 6 positioning pins.
The maximum allowed space between spirit level and the top of the positioning pins is 0,1 mm. Use a feeler gauge to check. Use
the same adjustment possibilities as described in step 3 to modify the height of this neighboring ILite rental foot. Do not modify
the height of the previous leveled ILite rental foot
Image 7-14
6. Level out the last aligned ILite rental foot in the transverse direction. Use the same adjustment possibilities as described in step
3.
Caution:
Do not place the spirit level upon the smaller foot profiles of the ILite rental foot but upon the main profile as illustrated.
7. Repeat step 5 and 6 until all ILite rental feet are aligned and leveled.