7. Basic setup procedures
B
A
Image 7-2
5. Create as much foot assemblies as required for your ILite display.
6. Place the foot assemblies with the positioning plates (Q) and pins (P) against each other on their final position.
Image 7-3
7. Level out the foot beams. If necessary place every 50 centimeters shim plates underneath the foot beams. This to prevent that
the beams bend.
8. Firmly attach the foot assemblies to the floor with fixings, or ballast, or both as required.
W
ARNING
stabilized with ballast. This to prevent possible tip over and sliding of the LED wall due to external influences.
It is the responsibility of the installer to ensure the stability of the LED wall. Note that the stability of the LED
wall depends on different parameters like: weight of display, height of display, width of display, length of used
foot beams and position of LED wall on foot beams (front - middle ?).
After the foot assemblies are installed on the desired location you can proceed with installing the foot beam
alignment tools between the foot assemblies. These alignment tools ensures a good alignment between the
foot assemblies, which results in minimum seams between the tile columns.
40
C
X > y
X
:
Foot beams of LED walls must always be firmly secured to the floor with fixings (preferred) or
D
E
y
R5976189 ILITE RENTAL DISPLAY 16/09/2005