8
9
-
Take note!
It is possible to deactivate the electric heating of the heating elements by pressing the button (f) on the programming panel.
Once deactivated, the relevant symbol (b) on the control panel will switch off to indicate this state. To reactivate the electric
heating, press the button (f) again: the symbol (b) will switch on.

5.7 TEMPERATURE PROBE CALIBRATION

Switch off the appliance.
Press and hold down the button
The "120" symbol will light up on the control panel and the temperature will automatically be set to 120°C. It is possible to check the
status of the heating elements with the relevant symbol (b): if lit, it means that the SET Temperature has been reached; if flashing, it
indicates the heating phase.
Using the buttons (i)
Each time that the buttons are pressed, probe calibration is changed by 0.5 °C.
If the symbol after "120" is flashing, this means that a change of 0.5 °C has been made; if it is lit, the change is 1 °C.
Take note!
Probe calibration is performed by the manufacturer during the appliance testing phase.
Only perform the above procedure after temperature probe replacement.
26
(h) and switch on the appliance.
or
(g) you can change this datum.