Milk Sensor Calibration (Optional); Delivery Group Individual Temperature Control - I.t.c. - (Optional) - La Spaziale COMPACT Instruction Manual For The Installer

Hide thumbs Also See for COMPACT:
Table of Contents

Advertisement

5.6

MILK SENSOR CALIBRATION (optional)

It is possible to calibrate the milk sensor in order to align the real temperature reading of the pT1000
(system M.A.T. milk sensor) to the preset temperature.
• Switch the appliance off.
• Press the button
The symbols 114 – 115 – 116 switch on on the control panel and they show the zero value of the
calibration range.
• It is possible to change the datum pressing the buttons
the button
to a value variation of +1° C sensed by the milk sensor .
• It is possible to go back negatively in the calibration range pressing the button
• Every time you press the button
switching off corresponds to a value variation of -1° C sensed by the milk sensor.
• Pressing the button
Switching the appliance off and on again, the datum is stored.
The milk sensor calibration has a range of -9° C, + 9°C.
5.7
DELIVERY GROUp INDIVIDUAL TEMpERATURE CONTROL - I.T.C. -
(optional)
This system makes it possible to set a different coffee brewing temperature for each delivery group.
The temperature of each group is independent from the temperature set in the boiler.
To vary the temperature on a group, use the
corresponding regulator alongside the group itself,
which can be reached through the opening in the top
of the, upper cup grid (14) (Pict 18).
Turn the adjustment screw anticlockwise to decrease
the temperature.
Turn the adjustment screw clockwise to increase the
temperature.
NOTE. Every full turn of the adjustment screw corresponds to a change of approximately 2 °C.
Changes must only be made to adapt the temperature of the delivery group to the coffee blend
being used, so as to improve the result in the cup.
84
LSI 001 -EN- REV. 06
(37) and, keeping it pressed, switch the appliance on.
(37) the symbols 117 - 118 - 119 etc. start flashing, every led switching on corresponds
(38) the symbols 113 – 112 -111 etc. start flashing, every led
(37) it is possible to go on positively in the calibration range.
INSTRUCTION MANUAL FOR THE INSTALLER
(37) and
(38) : every time you press
Temperature
regulator
(38).
18