Electrical; Environmental - Allen-Bradley 1336 REGEN Series User Manual

Line regeneration package
Table of Contents

Advertisement

Electrical

Environmental

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Specifications
Appendix B provides specification and supplemental information
for the 1336 REGEN Line Regeneration Package. Specifciations
apply to both the Regenerative DC Bus Supply and the
Regenerative Brake modes of operation unless noted.
AC Main Supply and Auxiliary Voltage
380-480VAC, 3Ø, +10%/–15% Nominal
48-62Hz
90-115VAC, 1Ø, ±10% Nominal
48-62Hz
Temperature
Ambient Operating Temperature IP00 (Open) 0-50˚C
Storage Temperature
Relative Humidity
Shock and Vibration
Shock
Vibration
ESD Susceptibility
IP20 (NEMA Type 1) Only
Agency Certification
U.L. Listed
CSA Certified
Appendix
IP20 (NEMA Type 1) 0-40˚C
All Ratings -40 to +85˚C
5-95% Non-Condensing
15g Peak for 11mSec. Duration (±1.0mSec.)
0.152mm (0.0006 In.) Displacement, 1g Peak
15kV
D
D
U L
U L
C
®
®
B

Advertisement

Table of Contents
loading

This manual is also suitable for:

1336r-vb1801336r-vb0781336r-vb048

Table of Contents