1336 REGEN Line Regeneration Package Catalog Number Explanation
1336R
VB
First Position
Second Position
Bulletin Number
Voltage
Letter
Voltages
VB
380-480VAC
50/60Hz
1336 REGEN Line Regeneration Package — Includes Converter (CNV) and Precharge (PRE)
Nominal Brake Rating
Frame
Input Amps
B
48.2
C
78.2
D
180.4
1321 Line Reactor — 380-480VAC
3% Line Reactor for Regenerative Brake Applications
IP 00 (Open)
No Enclosure
Bulletin Number
Cat. No.
1321
-3R55-B
-3R100-B
-3R200-B
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Allen-Bradley uses frame designations to identify the various
sizes of standard and configured drives. Throughout this manual,
frame sizes for 1336 REGEN Converter and Precharge Units may
be used instead of AC input kW or Amp ratings.
1336 REGEN
Converter Rating
Frame
Reference
B
C
D
The following diagram describes the 1336 REGEN Line
Regeneration Package catalog numbering scheme. The Line
Regeneration Package includes both the 1336REGEN Precharge
and 1336 REGEN Converter. The appropriate line reactor —
either 3% or 10% — is ordered separately,
180
AA
Third Position
Fourth Position
Nominal Current Rating
Enclosure Type
Code
kW (Amps)
Code
048 38.4 (48.2)
AA
078 62.3 (78.2)
AN
180 143.7 (180.4)
Output kW
38.4
62.3
143.7
IP 20 (NEMA Type 1)
General Purpose
Rated Amps
Cat. No.
Rated Amps
48
-3RA55-B
48
78
-3RA100-B
78
180
-3RA200-B
180
1336 REGEN
Precharge Rating
AC
Frame
Input kW Amp Rating
Reference
38.4
48.2
B
62.3
78.2
C
143.7
180.4
D
mods
Fifth Position
Human Interface Module, IP 20 (NEMA Type 1)
Type
Code
Description
NEMA 1 (IP 20)
HAB
Blank — No Functionality
HAP
Programmer Only
Open (IP 00)
IP 00 (Open)
No Enclosure
Code
VB048-AN
VB078-AN
VB180-AN
10% Line Reactor for DC Bus Supply Applications
IP 00 (Open)
No Enclosure
Cat. No.
Rated Amps
-3LR048-B
48
-3LR078-B
78
-3LR180-B
180
AC
Input kW Amp Rating
38.4
48.2
62.3
78.2
143.7
180.4
IP 20 (NEMA Type 1)
General Purpose
Code
VB048-AA
VB078-AA
VB180-AA
IP 20 (NEMA Type 1)
General Purpose
Cat. No.
Rated Amps
-3LRA048-B
48
-3LRA078-B
78
-3LRA180-B
180