Acquisition and Transfer Control Category
The Acquisition and Transfer controls, as shown by CamExpert, group parameters used to
configure the optional acquisition modes of the device. Parameters in gray are read only,
either always or due to another parameter being disabled. Parameters in black are user set
in CamExpert or programmable via an imaging application.
Features listed in the description table but tagged as Invisible are usually for Teledyne
DALSA or third party software usage—not typically needed by end user applications.
Acquisition and Transfer Control Feature Descriptions
The following table describes these parameters along with their view attribute and minimum
camera firmware version required. Additionally the firmware column will indicate which
parameter is a member of the DALSA Features Naming Convention (DFNC), versus the
GenICam Standard Features Naming Convention (SFNC not shown).
Display Name
Feature
Device Registers
DeviceRegistersStreamingStart
Streaming Start
Device Registers
DeviceRegistersStreamingEnd
Streaming End
Check Stream
DeviceRegistersCheck
Validity
Registers Valid
DeviceRegistersValid
Appendix A: GenICam Commands
Description
Announces the start of registers streaming
without immediate checking for consistency.
Announces end of registers streaming and
performs validation for registers consistency
before activating them.
Press to check the validity of the current
register set.
States if the current register set is valid and
consistent.
Device Version
& View
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
1.00
Beginner
DFNC
71
Need help?
Do you have a question about the Linea Color CL and is the answer not in the manual?