Camera Link Timing Diagrams - Dalsa Linea Color CL User Manual

4k and 8k color cmos line scan
Table of Contents

Advertisement

Camera Link Bit Definitions
Signal
CC1
CC2
CC3
CC4
For additional Camera Link documentation refer to the Teledyne DALSA Web site's
Knowledge Center application

Camera Link Timing Diagrams

RGB 8 bit CL Base, max line rate 10 kHz (8K), 20KHz (4K)
without AOI and 85 MHz CL Clock
This timing can be used for applications that require line rates only up to 10 kHz and
therefore can use Camera Link Base mode with only one cable.
The RGB output format is compatible with the Camera Link specification for Base RGB.
Values for red even numbered pixels are interpolated from the neighboring red odd
numbered pixels. Values for blue odd numbered pixels are interpolated from the
neighboring blue even numbered pixels. Line rates up to 48 kHz can be achieved by using
the Area of Interest (AOI) feature; where the smaller the AOI, the greater the potential line
rate.
Software and Hardware Setup 
Configuration
EXSYNC
Spare
Direction
Spare
Table 1: Camera Control Configuration
notes.