Preparations
Filling in engine lubrication oil directly
Fill in the engine lubrication oil into the cylinder
head at the intake (Fig. 3, item 1).
Filling quantities pursuant to the "Technical descrip-
tion of the CHP module".
Check the engine oil level with the dipstick (Fig. 3,
item 2):
-
remove the dipstick,
-
clean it with a clean, lint-free cloth,
-
insert it again right down to the stop,
-
pull it out once again.
WARNING
Do not fill in engine lubrication oil above
the MAXIMUM notch at the dipstick
(Fig. 4). The oil should level between
the two notches at the dipstick.
VITOBLOC 200 Operating instructions for the natural gas-fuelled CHP module
Fig. 3
Lubrication oil intake at the cover of the cylinder
head and dipstick
Fig. 4
Checking the oil level with the dipstick