3.12 12V 2000 M40A engine data: Separate heat exchanger,
reference conditions: 45 °C intake air temperature
Explanation:
CP Ref. value: Continuous power (CP)
FSP Ref. value: Fuel stop power (FSP)
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model
Application group
Intake air temperature
Raw-water inlet temperature
Barometric pressure
Site altitude above sea level
POWER-RELATED DATA (power ratings are net brake power to ISO 3046)
Number of cylinders
Engine rated speed
Continuous power ISO 3046 (10% overload capability) (design power DIN
6280, ISO 8528)
GENERAL CONDITIONS (for maximum power)
Number of cylinders
Intake air depression (new filter)
Intake air depression, max.
MODEL-RELATED DATA (basic design)
Number of cylinders
Cylinder configuration: V angle
Bore
Stroke
Cylinder displacement
Total displacement
Number of inlet valves, per cylinder
Number of exhaust valves, per cylinder
A
A
A
L
MS150031/06E 2016-010 | Technical Data | 75
12V
2000
M40A
3B
°C
45
°C
32
mbar
1000
m
100
12
rpm
1500
kW
575
12
mbar
15
mbar
50
12
Degrees
90
mm
130
mm
150
liter
1.99
liter
23.88
2
2