MTU 8V2000M40A Operating Instructions Manual page 130

Table of Contents

Advertisement

Fault
code
357
358
359
360
361
362
363
364
365
381
382
383
384
385
386
130 | Troubleshooting | MS150031/06E 2016-010
Alarm text
Meaning
OPEN_LOAD CYL.
Disconnection in wiring to sole-
B7
noid valve cylinder B7;
Misfiring
OPEN_LOAD CYL.
Disconnection in wiring to sole-
B8
noid valve cylinder B8;
Misfiring
OPEN_LOAD CYL.
Disconnection in wiring to sole-
B9
noid valve cylinder B9;
Misfiring
OPEN_LOAD CYL.
Disconnection in wiring to sole-
B10
noid valve cylinder B10;
Misfiring
POWER STAGE
Defect in ECU (solenoid valve
FAIL 1
power stage)
POWER STAGE
Defect in ECU (solenoid valve
FAIL 2
power stage)
STOP POWER
Solenoid valve or wiring or ECU
STAGE 1
defective
automatic engine shutdown
STOP POWER
Solenoid valve or wiring or ECU
STAGE 2
defective
automatic engine shutdown
STOP MV-WIRING
Solenoid-valve wiring faulty;
automatic engine shutdown
TRAN.OUT1
Binary transistor output plant 1
PLANT DEF
defective
TRAN.OUT2
Binary transistor output plant 2
PLANT DEF
defective
TRAN.OUT3
Binary transistor output plant 3
PLANT DEF
defective
TRAN.OUT4
Binary transistor output plant 4
PLANT DEF
defective
TRAN.OUT5
Binary transistor output plant 5
PLANT DEF
defective
TRAN.OUT6
Binary transistor output plant 6
PLANT DEF
defective
Task
1. Check wiring.
2. Contact Service.
1. Check wiring.
2. Contact Service.
1. Check wiring.
2. Contact Service.
1. Check wiring.
2. Contact Service.
Contact Service.
Contact Service.
1. Check wiring.
2. Try to re-start the engine (→ Page 114).
3. Contact Service.
1. Check wiring.
2. Try to re-start the engine (→ Page 114).
3. Contact Service.
1. Check wiring.
2. Try to re-start the engine (→ Page 114).
3. Contact Service.
Contact Service.
Contact Service.
Contact Service.
Contact Service.
Contact Service.
Contact Service.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents