2000 M40B Engine Data, Separate Heat Exchanger, Reference Condition: 25 °C Intake Air Temperature - MTU 8V2000M40A Operating Instructions Manual

Table of Contents

Advertisement

3.4 8V 2000 M40B engine data, separate heat exchanger,
reference condition: 25 °C intake air temperature
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated without changes (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model
Application group
Intake air temperature
Raw water inlet temperature
Barometric pressure
Site altitude above sea level
POWER-RELATED DATA (power ratings are net brake power to ISO 3046)
Number of cylinders
Engine rated speed
Continuous power ISO 3046 (10% overload capability) (design power DIN
6280, ISO 8528)
GENERAL CONDITIONS (for maximum power)
Number of cylinders
Intake air depression (new filter)
Intake air depression, max.
MODEL-RELATED DATA (basic design)
Number of cylinders
Cylinder configuration: V angle
Bore
Stroke
Cylinder displacement
Total displacement
Number of inlet valves per cylinder
Number of exhaust valves per cylinder
A
A
A
L
MS150031/06E 2016-010 | Technical Data | 51
8V 2000
M40B
3B
°C
25
°C
25
mbar
1000
m
100
8
rpm
1800
kW
400
8
mbar
15
mbar
50
8
Degrees
90
mm
130
mm
150
liter
1.99
liter
15.92
2
2