2000M41B Engine Data: Remote Heat Exchanger - MTU 8V2000M40A Operating Instructions Manual

Table of Contents

Advertisement

3.8 8V 2000M41B engine data: Remote heat exchanger
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power settings).
N Not yet defined value
- Not applicable
X Applicable
Engine model
Application group
Intake air temperature
Raw water inlet temperature
Barometric pressure
Site altitude above sea level
Power-related data (power ratings are net brake power to ISO 3046)
Number of cylinders
Rated engine speed
Continuous power ISO 3046 (10% overload capability, design power DIN 6280,
ISO 8528)
General conditions (for maximum power)
Number of cylinders
Intake depression (new filter)
Intake depression, max.
Model related data (basic design)
Number of cylinders
Cylinder arrangement: V-angle
Bore
Stroke
Cylinder displacement
Total displacement
Inlet valves per cylinder
Exhaust valves per cylinder
A
A
A
L
MS150031/06E 2016-010 | Technical Data | 63
8V2000M
41B
3B
°C
25
°C
25
mbar
1000
m
100
8
rpm
1800
kW
463
8
mbar
15
mbar
50
8
Degrees
90
(°)
mm
130
mm
150
Liters
1.99
Liters
15.92
2
2

Hide quick links: