Electronic Engine Monitoring Unit (EMU), optional
Functions:
• Data processing logistics for analog and binary signals;
• Interface for data transfer to CAN field bus for remote control and ship-side monitoring.
Electronic Gear Control Unit (GCU), ship-side wall-mounting
Functions:
• Date processing logistics for gear coupling control;
• Input/output signals as well as data transfer to CAN field bus for remote control and ship-side monitoring.
Monitoring in engine room
Engine control and monitoring unit (LOP)
Functions:
• Alphanumeric, monochrome LCD display for monitoring of measured values as well as alarms when limits
are violated;
• Pushbuttons for menu control and dimming unit;
• Combined control and display elements for local engine/gear control;
• Flashing light and horn for summary alarm in engine room;
• Interface to CAN field bus for connected, communicating monitoring system components.
SOLAS – Fire protection specifications
All fuel lines with fuel pressure >1.8 bar are fitted with SOLAS-compliant covers as per MTU standard
MTN5233.
All oil lines with oil pressure >1.8 bar are fitted with SOLAS-compliant covers as per MTU standard
MTN5233.
Fuel system covers