Start Interlock Limit Switch - Check - MTU 8V2000M40A Operating Instructions Manual

Table of Contents

Advertisement

7.22.3 Start interlock limit switch – Check
Preconditions
☑ Engine is stopped and starting disabled.
Note:
In its OFF position, the limit switch initiates start interlock, i.e. the engine cannot be started.
Start interlock limit switch –
Check
1.
Check if switch housing (1) and cover plate
(3) are mounted and the switch (2) is in the
on position.
2.
If switch housing (1) and/or cover plate (3)
is/are not mounted:
• Secure cover plate (3) with screws.
• Then install switch housing (1) with
screws, ensuring that the switch (2) is ac-
tuated by the cover plate (3).
3.
If switch housing (1) and cover plate (3) are
mounted, but switch (2) is in the off position:
• Make sure that the cover plate (3) at the
side of the switch (2) is not distorted.
• Release switch housing (1) and fit it with
screws in a position providing that the
switch (2) is on.
• If this is not possible, contact Service.
MS150031/06E 2016-010 | Accessories for (Electronic) Engine Governor / Control System | 221

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents