Changing mains voltage (only MVm versions)

General remarks

MVm machines (MultiVoltage manual) are suitable for operation with a mains
voltage of 380 - 460V and a mains voltage of 200 - 240V.
NOTE!
Machines are supplied with the 380 - 460V setting as standard.
If the mains voltage range needs to be reset, this must be done manually.
Detailed information can be found in the "Technical data" chapter.
Mains voltage
180 V ~
tolerance range
200 V - 240 V
342 V ~
380 V - 460 V
Changing mains
voltage
An electric shock can be fatal.
Before opening the device
200 V ~
- 10%
380 V ~
400 V ~
- 10%
WARNING!
Move the mains switch to the "O" position
Unplug the device from the mains
Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
Using a suitable measuring instrument, check to make sure that electrically
charged components (e.g. capacitors) have been discharged
230 V ~
240 V ~
253 V ~
+ 10%
460 V ~
+ 10%
506 V ~
23