Check motor.
Check for any play in the mix tank shaft.
Check valves, fittings, and plug on bottom of tank.
Check and tighten wire connections.
Check starters and overloads.
Check timers and relays.
Check the front of the panel; switches, voltmeter, potentiometer, etc.
Inspect fuses and breakers.
Check and set the proximity switches.
Inspect all welds and structural components for bends, cracks and damage.
Remove shields to inspect wheel, brushes and proximity switches.
Use compressed air to blow out any seeds and excess build-up that may
have occurred during operation.
Inspect RPM indicator.
Check and tighten wire connections.
Check starters and overloads.
Check timers and relays.
Check the front of the panel: switches and RPM indicator.
Inspect breakers.
Check and set the proximity switches.
Check the VFD .