4. Remove any boxes and the front leg from the drum of the treater.
5. Install the four legs provided and set up on a level surface, preferably concrete.
When all four legs are mounted in the same pin hole, the seed treater has a
slight slope to allow seed to travel through the machine. The pin holes are
approximately 2" apart.
If more slope is desired, the rear
legs can be dropped an additional
pin hole.
6. Anchor the seed treater in position to prevent
the machine from moving during operation.
7. Inspect machine thoroughly for screws, bolts,
fittings, etc. which may have come loose during
shipping.
8. Remove the calibration tube from the box and
install on the left side of the control panel using
the pins. Once the calibration tube is set in
place, connect the two chemical lines.
9. Remove the filter body from the control panel
and install on the front of the treater. The filter
is shipped in the control panel to avoid damage
in shipping.
10. If the treater is utilizing a flow meter, the flow
meter will need to be installed. Remove the
flow meter from the box and mount it on the
right hand side of the seed treater (seed
picture below). Connect the front and back
tubing to the flow meter. After the flow meter
has been installed, connect the cord from the
flow meter to the receptacle (page 31) located
on the bottom of the seed treater control panel.
11. Check and tighten all hose connections.
LP2000 with Seed Wheel
USC,
LLC
Calibration Tube
Filter
Page 15