Replacing The Connectors - Extron electronics HSA 400 Series Installation Manual

Rj-45 to rj-11 conversion kit
Table of Contents

Advertisement

im Vertrieb von
HSA 800, 802, 822 Installation, cont'd
4.
On the underside of the table, remove the two bolts that
secure the clamshell to the surface mount enclosure
(figure 2-2). Lift the enclosure out of the table. Ensure that
the cables connected to the AAPs do not snag or pull on
any protrusions.
Figure 2-2 shows an HSA 802. For the purposes of this
procedure, the HSA 800 and HSA 822 are physically
similar.
Remove 16
screws.
IEC Power Cord
RJ-45 Connectors
Figure 2-2 — Removing the HSA 802 from the table
www.camboard.de
2-4
RJ-45 to RJ-11 Conversion Kit • HSA 800, 802, 822 Installation
HSA 802
A
0.5
Hz
/60
12 5
- 50
INP
SE
UT
LE
CT
CO
MP
AU
UT
DI O
ER
Shroud
Mounting
Surface
AAP Cables
Clamshell
Flat Washer
Full Thread
Mounting Bolts
CAMBOARD Electronics

Replacing the Connectors

Tel. 07131 911201
RJ-45 to RJ-11 Conversion Kit • HSA 800, 802, 822 Installation
Fax 07131 911203
5.
On all AAP panels, remove the four screws on the right
and left sides of the AAP panel (figure 2-3). Retain the
screws. Lift the panels away from the enclosure as far as
the connected cables allow and then allow the panels to
dangle, supported by their connected cables.
Ensure that the edges of the AAP panels do not scratch
the finished surface of the top panel flange.
Figure 2-3 shows an HSA 802. For the purposes of this
procedure, the HSA 800 and HSA 822 are physically
similar.
Remove two screws
from each side.
H S
A 8
0 0
12 5
- 50
/6 0
H z
0. 5A
IN PU
SE
LE
T
CT
CO
A U
M PU
D IO
TE
R
Remove panel
from enclosure.
Spare Face Plate Screws (4)
Under Enclosure
Figure 2-3 — Removing the connector/AAP panel
Remove and retain the four screws in the corners of each
1.
side surface of the enclosure "cube". Remove the two
halves of the shroud.
Do not remove the screws in the
center of each side.
2.
Cut the tie wraps that bundle the CAT 6
cables.
3.
Inside the AAP panel, identify the RJ-45
connector to be replaced. With a
tweeker, push down on and gently twist
on the front of the RJ-45 connector detent to
disconnect the connector from the rear of the
AAP panel bezel plug-in.
ce-info@camboard.de
2-5

Advertisement

Table of Contents
loading

This manual is also suitable for: