Wiring works
Connection of the solar circulation pump / DHW Thermostat for DHW tank
Description
Solar pump /
DHW Thermostat
SOLAR PUMP / DHW Thermostat (N)
SOLAR PUMP / DHW Thermostat (L)
SOLAR PUMP /
DHW Thermostat
Power
32
EHS MONO Kit-EU_IM_05388A-04_EN.indd 32
No. of wires
2+ground
1 . Before the installation, control kit should be turned off .
2 . Using the appropriate equipment to correct position of terminal
block as shown on the diagram .
B25
3 . It is for control kit to inform that the Solar pump / DHW Thermostat
B26
is operating .
4 . Solar pump / DHW Thermostat is controlled by installer's handling .
And it send the signal to control kit depending on Solar pump /
DHW Thermostat conditions . In operating mode, signal shall be
Controller
around 230Vac B/W N&L . In non-operating mode, signal shall be
around 0Vac B/W N&L .
CAUTION
Max. A
Thickness
0 . 7 5mm
H05RN-F or
2
10 mA
H07RN-F
• Maximun allwable current of each terminal is below 10 mA .
• Ports number B25, B26 are for input port for detection
and they do not supply power to a Solar pump / DHW
Thermostat .
Supply Scope
Field supply (230 V~,
Input)