Wiring works
Temp. Sensor for DHW, Backup heater and a water Flow S/W
External wiring to control a switch of relay by a installer
Temp . sensor for backup heater
Relay
Temp . sensor for DHW
Flow s/w
Connecting a temp. sensor wire into DHW
1 . Put the sensor side of a temp . sensor wire into the designated location in a DHW .
2 . Connect the other side of the line at CNS042 .
Connecting a temp. sensor wire to outlet of backup heater
1 . Put the sensor side of a temp . sensor wire into the designated location in a backup heater .
2 . Connect the other side of the line at CNS047 .
Connecting a flow switch
1 . Install a flow switch in water line .
2 . Connect a wire of a flow switch into 'CNS041' connector .
Connecting a S/G(Smart grid)
1 . Install as above diagram .