Description
No. of wires
Mixing valve
Neutral (N)
B5
B3
CCW (L2)
B2
CW (L1)
Example of sensor installation (TW3 / TW4)
Weld the sensor holder on the selected location of the pipe and then insulate it .
When the pipe is a copper pipe
Pipe
Sensor clip
Insulator
• When the holder sensor cannot be welded on the pipe, fix the senor with aluminum tape and insulate it .
NOTE
EHS MONO Kit-EU_IM_05388A-04_EN.indd 43
Max. A
4
22 mA
> 0 . 7 5 mm
1 . Before the installation, control kit should be turned off .
2 . Using the appropriate equipment to correct position of terminal
Sensor
holder
Sensor
Aluminum tape
Thickness
, H05RN-F or H07RH-F
2
block as shown on the diagram .
When the pipe is not a copper pipe
Pipe
Sensor
Cable-tie
Insulator
Supply Scope
Field supply (230 V~, Input)
Sensor
Rubber tape
Sensor
2016-06-23 오후 3:43:11
43