Ametek Surgex UPS-17202-53R User Manual
Online battery backup, 2000/3000 va
Hide thumbs
Also See for Surgex UPS-17202-53R
:
User manual
(48 pages)
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
page
of
52
Go
/
52
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
1 Introduction
FCC Compliance
About this Manual
Safety
Safety Intended Use
General Warnings
Safety Notices
Battery Safety
Repacking of Unit
Safety Compliance
2 Overview
UPS Devices and Batteries
Packing List
Storage
Recharging the UPS During Storage
Environmental Conditions
Floor Loading
Ventilation
Rear Panel View
Model: UPS-17202-53R
Model: UPS-17302-60R
External Battery Cabinet
LCD Display
Rack Display
Tower Display
LCD: Display and Functional Description
3 Installation
Tower Installation
Rack Installation
Assembly Steps
Electrical Preparations
Battery Connections
4 Setting up UPS Parameters
Factory Default Settings
Changing Default Settings
Output Voltage Setting (Item 01)
Frequency Converter Enable/Disable (Item 02)
Output Frequency Setting (Item 03)
Bypass Mode Enable/Disable When the UPS Is off
Programmable Outlets Enable/Disable (Item 07)
Programmable Outlets Setting (Item 08)
LCD Display Direction Setting (Item 09)
Acceptable Input Voltage Range Setting (Item 10)
Number of External Battery Cabinets (Item 11)
5 UPS Operation
UPS Input Connection
LCD Display in Bypass Mode
LCD Display in Standby Mode
Turn on the UPS (Put the UPS in On-Line Mode)
LCD Display in On-Line Mode
Connect Devices to the UPS
The UPS in Battery Mode
LCD Display in Battery Mode
Turn off the UPS
6 Interfaces
Serial Interface COM
Interface Slot COM
7 Emergency Power off (EPO)
8 Maintenance
Cleaning
UPS Storage
Battery Testing
Replacing Batteries
9 Troubleshooting
Troubleshooting Table
Audible Alarm
LCD Display Abbreviation Index
Warning Indicators
UPS Fault
LCD Display in Fault Mode
Fault Reference Code
10 Appendix A: Specifications
UPS-17202-53R Specification
UPS-17302-60R Specifications
Extension Battery Cabinets
Advertisement
Quick Links
Download this manual
Online Battery Backup
UPS-17202-53R – 2000 VA UPS
UPS-17302-60R – 3000 VA UPS
User Manual
© 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com/
UM-UPS-Global-2-3kVA-REV-A
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Related Manuals for Ametek Surgex UPS-17202-53R
Battery Pack Ametek Surgex UPS-17602-52R User Manual
Online battery backup (48 pages)
UPS Ametek UPS-I000-OL User Manual
Online battery backup (44 pages)
UPS Ametek SurgeX UPS-1440-Li-ISO User Manual
Ups + isolation transformer battery backup (30 pages)
UPS Ametek SURGEX Security Plus II UPS-42100-85R User Manual
Online uninterruptible power supply (44 pages)
UPS Ametek Powervar Security Plus II User Manual
Online ups with isolation transformer 2kva / 3kva / 4kva / 5.2kva / 6kva / 8kva / 10kva (48 pages)
UPS Ametek Powervar Sinergy III 2kVA User Manual
Ups tower (38 pages)
UPS Ametek Powervar Security II Series Manual
(129 pages)
UPS Ametek 420VA Manual
Powervar security ii series rohs compliant uninterruptible power managers (70 pages)
UPS Ametek 387 Service Manual
(92 pages)
UPS Ametek ABCE702-11R Manual
Security ii rackmount series, uninterruptible power manager, for use with 700va, 1000va, 1440va, 2200va and 3000va (66 pages)
UPS Ametek GUPS 2400A–107 Operation Manual
(36 pages)
Summary of Contents for Ametek Surgex UPS-17202-53R
Page 1
Online Battery Backup UPS-17202-53R – 2000 VA UPS UPS-17302-60R – 3000 VA UPS User Manual © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com/ UM-UPS-Global-2-3kVA-REV-A...
Page 2
User Manual _________________________________________________________________ © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 3: Table Of Contents
2.9.1 Rack Display 2.9.2 Tower Display 2.10 LCD: Display and Functional Description 3. Installation 3.1 Tower Installation 3.2 Rack Installation 3.2.1 Assembly Steps 3.3 Electrical Preparations 3.3.1 Battery Connections © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 4
6. Interfaces 6.1 Serial Interface COM 3 6.2 Interface Slot COM 7. Emergency Power Off (EPO) 8. Maintenance 8.1 Cleaning 8.2 UPS Storage 8.3 Battery Testing 8.4 Replacing Batteries © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 5
9.4 Warning Indicators 9.5 UPS Fault 9.5.1 LCD Display in Fault Mode 9.5.2 Fault Reference Code 10. Appendix A: Specifications 10.1 UPS-17202-53R Specification 10.2 UPS-17302-60R Specifications 10.3 Extension battery cabinets © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 6: Introduction
The UPS generates, uses, and can radiate radio frequency energy. If installation and use is not in accordance with the instruction manual, it may cause harmful interference to radio communications. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 7: Safety Compliance
Depending on the type and rating of UPS device, certain configurations of battery extensions may be connected. These battery extensions may only be connected to the compatible basic UPS unit. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 8: General Warnings
Temperature Rating - Units are acceptable for use in a maximum ambient of 40 °C (104°F). • For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 9
• Transport the unit only in suitable packaging (protected against jolts and shocks). © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 10: Battery Safety
• Batteries should not be kept in storage for periods exceeding 6 © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 11: Repacking Of Unit
(e.g. 100μm polyethylene). Do not remove air from the packaging. When packing the unit for movement by common carrier, place in original or equivalent packaging container. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 12: Overview
2.1 UPS Devices and Batteries The following table provides an overview of the various versions of the device: UPS Model Battery Model UPS-17202-53R UPS-BPX-2000 UPS-17302-60R UPS-BPX-3000 © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 13: Packing List
2.4 Recharging the UPS During Storage Before storing, charge the UPS for five hours. During storage, recharge the battery in accordance with the following table: © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 14: Environmental Conditions
It is necessary to leave a minimum space of at least two inches (50 mm) in front and rear of the UPS to allow a flow of air. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 15: Rear Panel View
AC Input Input Circuit Breaker Emergency Power Off Function Connector (EPO) USB Communication Port RS232 Communication Port SNMP Intelligent Slot External Battery Connector Output Circuit Breaker Serial Number © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 16: External Battery Cabinet
User Manual _________________________________________________________________ 2.8.3 Model: External Battery Cabinet External Battery Connector Output Circuit Breaker Serial Number © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 17: Lcd Display
User Manual _________________________________________________________________ 2.9 LCD Display 2.9.1 Rack Display 2.9.2 Tower Display © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 18: Lcd: Display And Functional Description
Indicates that the battery charger is working. Battery information Indicates the battery level by 0-25%, 26-50%, 51-75%, and 76-100%. Indicates low battery. Indicates that there is something wrong with the battery. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 19: Installation
Assemble two feet each with an extension as one tower stand. • Align the two stands. • Put the UPS module and external battery cabinet in the stands. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 20: Rack Installation
Please use the supplied fasteners to attach the supplied mounting brackets to the UPS or external battery cabinet. If external batteries are included in your installation, please mount them © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 21: Assembly Steps
Step 2. Use four M6 screws to mount the right and left rail sliders to the two back posts of the four-post rack. Refer to the following figure: © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 22
Add mounting ears to both sides of the unit. Refer to the following figure: Step 5. Install UPS and external battery cabinet. Refer to the follow- ing figure. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 23: Electrical Preparations
UPS. DO NOT USE any other extended battery cabinet for the corresponding UPS. UPS Model Battery Cabinet Model UPS-17202-53R UPS-BPX-2000 UPS-17302-60R UPS-BPX-3000 © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 24
6. Connect the other end of the battery cable to the UPS. 7. For multiple extended battery cabinets, connect the supplied bat- tery cables as shown in the figure below. 8. Set the circuit breaker to the “ON” position. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 25
User Manual _________________________________________________________________ © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 26: Setting Up Ups Parameters
Avoid using extension cords. If the mains voltage is within the acceptable range, the UPS will enter bypass mode. “BYPASS” will be displayed in the UPS status window on the LCD display. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 27
4. Press the “UP” or the “DOWN” button to scroll thru all of the avail- able settings for that parameter. 5. When you see the setting that you want for that parameter press the “LEFT ARROW” button to choose that setting. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 28: Output Voltage Setting (Item 01)
50: output frequency is 50Hz 60: output frequency is 60Hz If converter mode is enabled, the following output frequency can be chosen: 50: output frequency is 50Hz 60: output frequency is 60Hz © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 29: Bypass Mode Enable/Disable When The Ups Is Off
4.2.6 Programmable Outlets Setting (Item 08) Interface Setting 0-999: Backup time in minutes that programmable output receptacles will operate in battery mode. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 30: Lcd Display Direction Setting (Item 09)
The following number of external battery cabinets can be chosen: 0: No External Battery Cabinet. 1: One External Battery Cabinet. 2: Two External Battery Cabinets. 3: Three External Battery Cabinets. 4: Four External Battery Cabinets. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 31: Ups Operation
UPS will not supply output power to the load. See Section 5.0 “ LCD Display in Standby Mode”. 5.1.1 LCD Display in Bypass Mode Rack Display Tower Display © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 32: Lcd Display In Standby Mode
After the UPS has been turned on, devices (load) can now be connect- ed to the UPS. For socket-type outputs, there are two kinds of outputs: programmable outlets and general-purpose outlets. Connect non-critical © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 33: The Ups In Battery Mode
UPS will automatically shut down. At this time, users could switch off any non-critical loads to disable the shutdown alarm and pro- long the backup time. If no more load can be removed at this time, © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 34: Lcd Display In Battery Mode
If instead the bypass is disabled, the UPS will enter standby mode. In this mode the UPS will not supply power to the load. The UPS will also charge the batteries. See Section 5.0 “LCD Display in Standby Mode”. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 35: Interfaces
6.1 Serial Interface COM 3 The 9-pole SUB-D connector (pin contacts) contains RS232 compatible signals. NOTE: The interface COM RS232 is electrically isolated from primary UPS circuits. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 36: Interface Slot Com
Keep Pin 1 and Pin 2 closed (shorted) for UPS normal operation. To acti- vate the EPO function, remove the wire between Pin 1 and Pin 2. Pin 1 and Pin 2 shown in closed status. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 37: Maintenance
UPS and/or batteries. Exhausted rechargeable batteries are classified as “harmful toxic waste” and as such the law de- mands that they be disposed of/recycled by an authorized recycling center. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 38
• When replacing batteries, replace with the same type and number of batteries or battery packs. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 39
“snaps” out of position. Remove the left side of the front cover and place it in a safe place. Refer to the following figure: © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 40
Disconnect the battery connectors. Refer to the following figure: 4. Pull out the battery pack. Refer to the following figure: 5. Slide in replacement battery pack. Refer to the following figure: © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 41
8. Carefully pack used battery pack and send to authorized recycle center. Do not discard electrical waste or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 42: Troubleshooting
UPS is locked in the from the UPS output. Then bypass mode. Connected shut down the UPS and devices are fed directly by restart it. the mains. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 43: Audible Alarm
Low Battery Alarm Beeps Once Every Second Overload Alarm Beeps Twice Every Second Fault Alarm Beeps Continuously 9.3 LCD Display Abbreviation Index Abbreviation Display Content Meaning Enable Disable Escape © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 44: Warning Indicators
Beeps Once Every Second Site Wiring Fault Beeps Once Every Second EPO Enable Beeps Once Every Second Over Temperature Beeps Once Every Second Charger Failure Beeps Once Every Second © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 45: Ups Fault
Bus Over Inverter Output Short Bus Under Battery Voltage Too High Bus Unbalance Battery Voltage Too Bus Short Circuited Over Temperature Inverter Soft Start Fail Overload High Inverter Voltage © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 46: Appendix A: Specifications
Battery Voltage (Float / Nominal) 54.7/48.0 VDC Charger Current 1.0 A Backup Time (Full Load) > 3.6 Minutes Communications Interface USB / RS-232 Shipping Weight 60.0 lbs. / 27.3 kg. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 47
User Manual _________________________________________________________________ © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 48: Ups-17302-60R Specifications
Battery Voltage (Float / Nominal) 82.1/72.0 VDC Charger Current 1.0 A Backup Time (Full Load) > 3.6 Minutes Communications Interface USB / RS-232 Shipping Weight 83.0 lbs. / 37.7 kg. © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 49
• Internal Relay Contact Card (Optional) Immunity • Circuit Breaker • IEC61000-4-5, Surge Immunity • IEC61000-4-6, CS • IEC61000-4-8, Power Frequency Magnetic Field • IEC61000-2-2, Low Frequency Signal • RoHS © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 50: Extension Battery Cabinets
Runtimes are affected by batter age, ambient temperature, site specific usage patterns and load conditions > 16 hrs. > 16 hrs. > 16 hrs. > 16 hrs. > 16 hrs. 1260 1280 1440 1600 © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 51
Runtimes are affected by batter age, ambient temperature, site specific usage patterns and load conditions > 16 hrs. > 16 hrs. > 16 hrs. > 16 hrs. > 16 hrs. 1200 1440 1680 1920 2160 2400 © 2019 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / surgex.com...
Page 52
User Manual _______________________________________________________________...
This manual is also suitable for:
Surgex ups-17302-60r
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL