IC-KP-B5-V23
Commands
The status '05h' is only output when a tag leaves the detection range or is not yet
within the detection range. If two tags enter the read range one immediately after
the other, the status '05' is not issued between the two readings.
Extended commands for IQH2-... read/write heads
read param (RP)
Command:
Byte
1)
Byte 0
1)
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
This byte is only used with the TCP/IP and MODBUS TCP/IP protocol.
1)
Response:
Byte
1)
Byte 0
1)
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
...
2)
Byte N
This byte is only used with the TCP/IP and MODBUS TCP/IP protocol.
1)
N = <DataLength> + 6
2)
Contents
Telegram length, high byte
Telegram length, low byte
Command code (BEh)
Reserved/Ident channel/Toggle bit
System code
System code
Parameter type
Parameter type
Contents
Telegram length, high byte
Telegram length, low byte
Command code (BEh)
Reserved/Ident channel/Toggle bit
Status
Reply counter
Data 00 ... FFh
Data 00 ... FFh
Data 00 ... FFh
Bit no.
7
6
5
4
3
0
0
0
0
0
0
0
0
0
0
1
0
1
1
1
-
<Channel>
<SystemCode> (high byte)
<SystemCode> (low byte)
<ParamTyp> (high byte)
<ParamTyp> (low byte)
Bit no.
7
6
5
4
3
0
0
0
0
0
0
0
0
0
1
1
0
1
1
1
0
<Channel>
<Status>
<ReplyCounter>
<Data>
<Data>
<Data>
2
1
0
0
0
0
1
0
0
1
1
0
<T>
2
1
0
0
0
0
0
1
1
1
1
0
<T>
69
Need help?