IC-KP-B5-V23
Commands
Type IDC-...-1K tags can be programmed in such a way that they are compatible
with the type ICC-... read only carriers. This programming occupies the first 8
bytes in the tag. The read/write commands can be used to access the remaining
memory.
You must set the tag type '50' in order to program type IDC-...-1K tags. To do this,
transmit the command SX or EX.
The value range contains 7 characters:
the first 3 characters contain the values 0 ... F (hexadecimal code)
the last 4 characters contain the values 0 ... 9 (decimal code)
You must select the tag type '50' (ICC-...) beforehand in order to read out this
code. If a "read only code" command is executed when the tag type '50' (IDC-...-
1K) is set, the 4-byte read only code for this tag is issued.
59