1.3.3 Connecting the field bus

1−18
Please note
Note that only the plugs from Festo guarantee compliance
with protection class IP65/IP67.
If the continuiing bus interface is not connected:
Seal the continuing bus interface with the protective cap
·
supplied.
Connecting with sub−D plugs of other manufacturers:
Replace the two flat screws with bolts
·
(type UNC4−40/M3x6).
Connect the cable screening/shield to the plug housing.
·
Connecting with the field bus plugs from Festo
Observe the fitting instructions for the field bus plugs.
·
You can connect the CPX valve terminal to the field bus easily
with the field bus plugs from Festo.
Connection
Incoming bus interface
Continuing bus interface
Fig. 1/5 shows the connection with the field bus plugs from
Festo.
Field bus plug type
FBS−SUB−9−BU−IB−B
FBS−SUB−9−GS−IB−B
Festo P.BE−CPX−FB6−EN en 0402b