Decode Session Timeout; Timeout Between Decodes - Newland NLS-HR42 User Manual

2d handheld barcode scanner
Table of Contents

Advertisement

Decode Session Timeout

This parameter sets the maximum time decode session continues during a scan attempt. It is programmable in 1ms
increments from 1ms to 3,600,000ms. When it is set to 0, the timeout is infinite. The default setting is 3,000ms.
Set the decode session timeout to 1,500ms:
1.
2.
3.

Timeout between Decodes

Timeout between Decodes sets the time period between the end of one decode session and the start of next session. It is
programmable in 1ms increments from 1ms to 10,000ms. The default timeout is 500ms. This feature is only applicable to
the Continuous modes.
Set the timeout between decodes to 800ms:
1.
2.
3.
Decode Session Timeout
Scan the Decode Session Timeout barcode.
Scan the numeric barcodes "1", "5", "0" and "0" from the "Digit Barcodes" section in Appendix.
Scan the Save barcode from the "Save/Cancel Barcodes" section in Appendix.
Timeout between Decodes
Scan the Timeout between Decodes barcode.
Scan the numeric barcodes "8", "0" and "0" from the "Digit Barcodes" section in Appendix.
Scan the Save barcode from the "Save/Cancel Barcodes" section in Appendix.
@ORTSET
@SCNINV