IEC 60068-2-14
IEC 60068-2-30
IEC 60068-2-78
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-3
IEC 60068-2-31
RUGGEDCOM RST2228P
Installation Manual, 12/2019, C79000-G8976-1403-05
Test
IEC 60068-2-2
Change of
Temperature
Humidity (Damp
Heat, Cyclic)
Humidity (Damp
Heat, Steady State)
IEC 60529
Description
Dry Heat
Test Bd
Test Nb
Test Db
Test Cab
Vibration
Shock
Bump
Seismic
Ingress Protection
Free Fall
Test Ec
6.2 EMC and Environmental Type Tests
Test Levels
85 °C (185
°F), 16 Hours
5 Cycles, -40 to 85°
C (40 to 185° F)
93% upper tem-
perature, 97% low-
er temperature
55 °C (131
°F), 6 Cycles
10 days @ 55 °C
(131 °F) and 93%
Relative Humidity
Level 2 (2 g @
10 to 150 Hz)
Level 2 (30
g @ 11 mS)
Level 1 (10
g @ 16 mS)
Method A, Class 2
IP4x
25 cm
Certification
Severity Levels
 
 
 
 
Class 2
Class 2
Class 1
Class 2
 
 
47