Siemens SIMATIC NET RUGGEDCOM RST2228P Installation Manual page 55

Hide thumbs Also See for SIMATIC NET RUGGEDCOM RST2228P:
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
IEC 61000-4-29
IEC 60255-27
a
Siemens-specified severity levels
EMC Immunity Type Tests per IEEE 1613
Environmental Type Tests
46
Test
Voltage Dips
and Interrupts
Dielectric Strength
HV Impulse
Description
ESD
Radiated RFI
Fast Transient
Oscillatory
HV Impulse
Dielectric Strength
Damped Oscillat-
ing Magnetic Field
Test
IEC 60068-2-1
Cold Temperature
Description
DC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
POE Power Ports
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Enclosure Ports
Description
Test Ad
Test Levels
Severity Levels
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Fail-Safe
Relay Output)
2.9 kVdc
2 kV
5 kV (Fail-Safe
Relay Output)
5 kV
5 kV
1 kV
Test Levels
± 8 kV
± 15 kV
35 V/m (80% modulation)
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
2.5 kV common mode
2.5 kV common and 1.0
kV Differential Mode
2.5 kV common and 1.0
kV Differential Mode
5 kV (Failsafe Relay)
5 kV
5 kV
2 kV (Failsafe Relay Output)
2.9 kVdc
2 kV
100 A/m (peak) for 1 s
(100 kHz and 1 MHz)
Test Levels
Severity Levels
-40 °C (-40
°F), 16 Hours
Installation Manual, 12/2019, C79000-G8976-1403-05
 
 
 
 
 
 
 
 
Severi-
ty Levels
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5
 