4) External interface circuit
I/O
Input
Input
5) Wiring instructions
A high speed pulse input is sensitive to the external noise and should be handled with special care. When wiring the built-in
high speed counter of MASTER-K120S, take the following precautions against wiring noise.
(1) Be sure to use shielded twisted pair cables. Also provide Class 3 grounding.
(2) Do not run a twisted pair cable in parallel with power cables or other I/O lines which may generate noise.
(3) Before applying a power source for pulse generator, be sure to use a noise-protected power supply.
(4) For 1-phase input, connect the count input signal only to the phase A input; for 2-phase input, connect to phases A and B.
Internal circuit
3.3 kΩ
3.3 kΩ
3.3 kΩ
3.3 kΩ
3.3 kΩ
3.3 kΩ
3.3 kΩ
3.3 kΩ
Termi
Signal name
nal
1Phase
2Phase
No.
Ch0
P00
Input
pulse
Ch1
P01
Input
pulse
Ch2
P02
Input
pulse
Ch3
P03
Input
pulse
COM
Common
0
Ch0
P04
Preset
input
Ch1
P05
Preset
input
Ch2
P06
Preset
input
Ch3
P07
Preset
input
COM
Common
0
7-3
Operati
Input warranted
on
Ch0 A
On
20.4~28.8V
Phase
Off
6V or lower
Input
Ch0 B
On
20.4~28.8V
Phase
Off
6V or lower
Input
Ch2 A
On
20.4~28.8V
Phase
Off
6V or lower
Input
Ch2 B
On
20.4~28.8V
Phase
Input
Off
6V or lower
Ch0
On
20.4~28.8V
Preset
Off
6V or lower
input
On
20.4~28.8V
-
Off
6V or lower
Ch2
On
20.4~28.8V
Preset
Off
6V or lower
input
On
20.4~28.8V
-
Off
6V or lower
voltage