LG MASTER-K 120S Series User Manual page 193

Programmable logic controller
Table of Contents

Advertisement

Chapter 8 Communication Functions
(2) 1:1 connection with a monitoring device like PMU
1
2
3
4
5
Female Type
PMU(LGIS)
RS-485 interface
RS-232C interface
PMU
Pin No.
1
2
6
7
3
8
4
9
5
6
7
8
9
PMU
Connection method and signal direction
485+
485-
MASTER-K120S main unit
Pin assignment and direction
8-3
MASTER-K120S main
unit
Pin no.
Signal
1
5V
2
RXD1
3
TXD1
4
RXD2
5
SG
6
5V
7
TXD2
8
SG
9
SG
MASTER-K120S main unit
485+
485-

Advertisement

Table of Contents
loading

Table of Contents