Electrical Equipment in Explosion Hazard Zones:

Installation Instructions

Installation per
EN 60079-14
(VDE 0165/1 Part 1)
Potential
Compensation
Electrostatic Charges Avoid electrostatic discharges. Observe the "Guidelines for Avoiding Ignition Risks
Testing Prior to Initial
Use
42/24-30 EN Rev. 1
The electrical device shall be installed according to EN 60079-14 (VDE 0165 Part 1)
"Electrical Equipment in Gas Explosion Hazard Areas, Part 14: Electrical Equipment
in Explosion Hazard Areas".
The requirements of EN 60079-14 and DIN VDE 0100 Part 410 "Protection Against
Electrical Shock" and Part 540 "Grounding, Protective Leads and Potential
Compensation Leads" shall be observed.
Due to Electrostatic Discharges" published by the Executive Committee for the
Industrial Professional/Trade Associations.
The operator is required to have the electrical system tested for proper operation
by a qualified electrician prior to using the unit for the first time.
If the manufacturer or installer certifies that the electrical system meets ElexV
requirements, no inspection prior to initial use is required.
EL6010 Gas Analyzer in Category 2G Operator's Manual
71