Temperature Information:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until "Menu
Info" is displayed and press ENTER.
2. Press the UP or DOWN buttons until "TempInfo" is displayed and press ENTER.
3. The current temperature will now be displayed. Press the MENU button to exit.
Model Information:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until "Menu
Info" is displayed and press ENTER.
2. Press the UP or DOWN buttons until "Model Inf" is displayed and press ENTER.
3. The model name will now be displayed. Press the MENU button to exit.
Software Information:
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons until "Menu
Info" is displayed and press ENTER.
2. Press the UP or DOWN buttons until "Software" is displayed and press ENTER.
3. The current software version will now be displayed. Press the MENU button to exit.
Slave Setting - With this function you can set the unit as a "Slave" in Master-Slave configuration.
1. Plug the fixture in and press the MODE button and press the UP or DOWN buttons until
"Slave" is displayed, and press ENTER.
2. The unit is now set as a "Slave" in a Master-Slave configuration.
Manual Control - With this function you can manually adjust the dimmer, colors, and strobing.
1. Plug the fixture in and press the MODE button and press the UP or DOWN buttons until
"Manual" is displayed, and press ENTER.
2. Press the UP or DOWN buttons to scroll through dimmer, colors, and strobe.
Note: See the system menu on page 20.
3. Press ENTER to select the function you woud like to adjust and use the UP and DOWN buttons
to make the adjustments.
4. Once you have made your desired adjustments, press the ENTER button.
32 Hex Panel IP/32 Hex Panel IP Pearl
Master-Slave Configuration:
This function will allows you to link units together to run in a Master-Slave set-up. In a Master-Slave
set up one unit will act as the controlling unit and the others will react to the controlling units built-in
programs. Any unit can act as a Master or as a Slave however, only one unit can be programmed to
act as the "Master."
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit. Use standard XLR data
cables to link your units together. Remember that the Male XLR connector is the input and the
Female XLR connector is the ouput. The first unit in the chain (master) will use the female XLR
connector only. The last unit in the chain will use the male XLR connector only.
2. Connect the first "Slave" unit to the "Master."
3. Set the "Master" unit to your desired mode of operation. On the "Slave" unit(s) press the MODE
button and press the UP or DOWN buttons until "Slave" is displayed and press ENTER.
4. The slave unit(s) will now follow the master unit.