Power Linking I Trouble Shooting I Cleaning - ADJ 32 HEX PANEL IP User Instructions

Hide thumbs Also See for 32 HEX PANEL IP:
Table of Contents

Advertisement

32 Hex Panel IP/32 Hex Panel IP Pearl
With this feature you can connect the fixtures to one another using the power cable input and
output sockets.
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER
CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON
THIS FIXTURE! CHECK SILK SCREEN FOR MAX AMPS.
32 Hex Panel IP/32 Hex Panel IP Pearl
Listed below are a few common problems the user may encounter, with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are wired correctly (pin 3 is "hot"; on
some other DMX devices pin 2 may be 'hot'). Also, check that all cables are connected to the right
connectors; it does matter which way the inputs and outputs are connected.
32 Hex Panel IP/32 Hex Panel IP Pearl
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be carried
out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
3. Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog residue,
dust, dew).
ADJ Products, LLC - www.adj.com - 32 Hex Panel IP/32 Hex Panel IP Pearl User Manual Page 30
Multiple Unit Power Linking
Trouble Shooting
Cleaning

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

32 hex panel ip pearl

Table of Contents