Danfoss VLT Automation Drive FC 300 Operating Instructions Manual page 125

Hide thumbs Also See for VLT Automation Drive FC 300:
Table of Contents

Advertisement

®
VLT
Automation Drive FC 300
Operating Instructions High Power
No.
61
62
63
64
65
66
67
68
70
71
72
80
90
91
100-
199
250 New spare part
251 New Type Code
Table 6.2: Alarm/Warning code list
(X) Dependent on parameter
1) Can not be Auto reset via Par 14-20
A trip is the action when an alarm has ap-
peared. The trip will coast the motor and can
be reset by pressing the reset button or make
a reset by a digital input (Par. 5-1* [1]). The
origin event that caused an alarm cannot
damage the drive or cause dangerous condi-
tions. A trip lock is an action when an alarm
occurs, which may cause damage to drive or
Description
Tracking Error
Output Frequency at Maximum Limit
Mechanical Brake Low
Voltage Limit
Control Board Over-temperature
Heat sink Temperature Low
Option Configuration has Changed
Safe Stop
Illegal FC configuration
PTC 1 Safe Stop
Dangerous Failure
Drive Initialized to Default Value
Encoder Loss
Analogue input 54 wrong settings
See Operating Instructions for MCO
305
MG.33.U1.02 - VLT
®
is a registered Danfoss trademark
Warning
Alarm/Trip
Alarm/Trip Lock
(X)
(X)
X
(X)
X
X
X
X
X
X
(X)
1)
(X)
X
X
X
1)
X
X
(X)
(X)
X
X
X
X
connected parts. A Trip Lock situation can only
be reset by a power cycling.
LED indication
Warning
Alarm
Trip locked
6. Warnings and Alarms
Parameter
Reference
4-30
2-20
5-19
5-19
5-19
1)
17-61
S202
14-23
yellow
flashing red
yellow and red
6
125