Uploading Pump Program Settings To The Pump - Graco G3 Series Instructions Manual

Max automatic lubrication pump, for dispensing of nlgi grades #000 to #2 greases and oil with at least 40cst, for professional use only, not approved for use in explosive atmospheres or hazardous locations
Hide thumbs Also See for G3 Series:
Table of Contents

Advertisement

Max Model Setup
for 3 seconds to store the current setup to the USB
flash drive.
7. "data" is displayed while the unit is
downloading and storing the configu-
ration on the USB drive.
8. When configuration is stored, "done"
is displayed.
9. G3 pump restarts cycle in the OFF mode.
10. Remove the USB flash drive.
Uploading Pump Program
Settings to the Pump
1. Plug the USB flash drive into the USB port.
NOTE:
The USB flash drive must contain file
GRACO/G3Config/g3config.bin (for 0209 and
earlier) or GRACO/Config/config.bin (for 0706
or later).
NOTE: 0707 pumps can take either file setting
to upload, but earlier pumps cannot. File names
and folders may need to be changed manually
when importing settings to an earlier version
pump from a later version.
The G3 pump stops pumping as soon as the
USB flash drive is plugged into it.
2. The system automatically begins downloading data
to the USB drive.
3. "data" is displayed while the system
is downloading files.
4. When download is finished, "done" is
displayed.
5. G3 pump restarts cycle in the OFF mode.
6. After the download is com-
plete, press and hold the
RESET button and UP
ARROW button for 3 seconds
to upload the setup stored in the USB flash drive.
7. "data" is displayed while the unit is
uploading the configuration data.
40
8. When upload is finished, "done" is
displayed.
9. G3 pump restarts cycle in the OFF mode.
10. Remove the USB flash drive.
11. After the USB flash drive is
removed, press and hold the
UP and DOWN ARROW but-
tons for 3 seconds to enter
the SETUP MODE (see
Entering Setup Mode, page 31).
12. In SETUP MODE, set the YEAR, MONTH, DATE
and TIME (see Setting the Real Time Clock, page
32).
13. After pressing the ENTER button to set
the TIME, press the RESET button to
exit the SETUP MODE.
Viewing the UNIT DMS ID Number
1. In RUN mode, press and hold the
DOWN ARROW button.
2. The Unit DMS ID number displays. The
unit continues to normal operation while
the DMS ID is displayed.
3. Release the DOWN ARROW button after viewing
the DMS ID number.
332305J