Graco G3 Series Instructions Manual page 61

Max automatic lubrication pump, for dispensing of nlgi grades #000 to #2 greases and oil with at least 40cst, for professional use only, not approved for use in explosive atmospheres or hazardous locations
Hide thumbs Also See for G3 Series:
Table of Contents

Advertisement

With machine count set, the Rest Cycle (Pump OFF) is
ended when the machine count reaches zero (0000).
Machine Count
A set number of triggered counts.
The LED next to 1-2-3 illuminates (F
The display indicates the number of machine
counts remaining.
The example shown in F
remaining number of machine counts is 0045.
HH
MM
SS
ON
MM : SS
HH : MM
C
1
P
C
C
2
P
C
P
3
P
F
. 52
IG
332305J
. 52).
IG
. 52 shows the
IG
##
!
OFF
1 2 3
Backup Time
In Machine Count mode, if a Backup Time (maximum
rest time) has been set:
The LED next to 1-2-3 illuminates (F
The display shows the amount of time remain-
ing till a fault or lubrication mode (pump ON).
The example shown in F
and 17 minutes remaining until a fault or lubrica-
tion mode (pump ON) occurs.
If the Machine Count requirements are met the
unit will exit the Rest Mode (Pump OFF) and
enter the Lubrication Mode (Pump ON).
HH
MM
SS
ON
MM : SS
C
1
P
C
C
2
P
C
P
3
P
F
. 53
IG
OFF Time
In Max models if the Machine Count is set to 0000 then
Reset Mode (Pump OFF) is controlled with OFF Time
(see Time Control, page 58).
Run Mode
. 53).
IG
. 53 shows 4 hours
IG
##
!
OFF
HH : MM
1 2 3