Graco G3 Series Instructions Manual page 62

Max automatic lubrication pump, for dispensing of nlgi grades #000 to #2 greases and oil with at least 40cst, for professional use only, not approved for use in explosive atmospheres or hazardous locations
Hide thumbs Also See for G3 Series:
Table of Contents

Advertisement

Run Mode
Additional Controls
Venting
In Max models a Vent Time can be set using the
Advanced Programming mode (page 51). This is typi-
cally done in a Pressure Based System (P1) to allow
injectors to reset.
Unit vents for a set amount of time (not dis-
played).
The LED's next to C/P1, C/P2, C/P3 flash while
unit is venting.
If Machine Count is set, the display will alternate
between machine counts remaining and backup
time (Max Model Rest Mode, page 60).
If Machine Count has been set the LED next to
1-2-3 illuminates (F
If Machine Count has not been set the display
shows OFF Time (See Time Control, page 58).
If Machine Count has not been set the LED next
to the clock in the OFF field illuminates (See
Time Control, page 58).
While unit is venting, VEnt will display and alter-
nate with Machine Count and the Backup Time
or the OFF Time.
Prelube / Prelube Delay
In all models a power OFF/ON cycle can be controlled
with the Prelube and Prelube Delay functions.
Prelube
The Prelube function has been selected. Prelube delay
is set to 00:00:
Power to the unit cycles OFF then ON.
Unit immediately begins a lubrication cycle.
Max Model - display shows Cycle/Pres-
sure/Backup Time (See Max Model Lubrication
Mode Controls, page 58).
Prelube Delay
The Prelube function has been selected. Prelube delay
is set to something other than 00:00:
Power to the unit cycles OFF then ON.
Unit immediately begins the Prelube Delay
count down until the lubrication cycle begins.
62
. 52, page 61).
IG
The LED next to the clock in the OFF field is illu-
minated (F
. 54).
IG
The Prelube LED lights (F
The display shows time remaining until lubrica-
tion cycle begins. The example shown in F
shows 8 minutes and 14 seconds left until a
lubrication cycle begins.
HH
MM
ON
MM : SS
C
1
P
C
C
2
P
C
P
3
P
F
. 54
IG
Manual Run Cycle
To run an extra (non-programmed) lubrica-
tion cycle, push the Manual Start button.
NOTE: Manual Run option is not available while unit is
in Vent Mode.
. 54).
IG
SS
##
!
OFF
HH : MM
1 2 3
332305J
. 54
IG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3-g-24mx-2l0l00-10cv00r0G3-g-acmx-2lfl00-1d0v0000G3-g-acmx-2l0l00-1d0v0000G3-g-24mx-2lfl00-10cv00r0G3-g-12mx-2l0l00-1dmva2r3G3-g-24mx-2l0l00-1dmva2r3 ... Show all

Table of Contents